Skip to main content

Table 3 Prevalence of dosing errors committed by mothers, binomial effect size display, odds ratios of reduction in dosing errors and Cohen’s d (effect size) of the pictogram intervention (TPMS)

From: Can use of pictograms reduce liquid medication administration errors by mothers? An interventional study

Device

Doses (mL)

TOMS

TPMS

BSED (%)

OR** (95% CI)

Effect size (dcohen)

Incorrect

Correct

Incorrect

Correct

n = 310 (%)a

n = 310 (%)a

n = 310 (%)a

n = 310 (%)a

Dropper

0.5

185 (60)

125 (40)

38 (12)

272 (88)

48

10.55 (7.05–16.02)

1.86

 

1

196 (63)

114 (37)

28 (9)

282 (91)

54

17.22 (11.07–27.44)

3.01

Measuring cup

2.5

192 (62)

118 (38)

26 (8)

284 (92)

54

17.68 (11.25–28.51)

2.89

 

5

206 (66)

104 (34)

23 (7)

287 (93)

59

24.56 (15.3–40.65)

6.4

Calibrated spoon

2.5

215 (69)

95 (31)

38 (12)

272 (88)

57

16.11 (10.69–24.67)

3.83

 

5

210 (68)

100 (32)

41 (13)

269 (87)

55

13.71 (9.19–20.75)

2.9

  1. Text only measurement session (TOMS) and text plus pictogram measurement session (TPMS); BSED: Binomial effect size display (intervention success); OR odds ratios** (P < 0.001 for all OR displayed)